program a Sequence Program Step.
Syntax
Parameters
Category
return the programmed STEP delay and operation. The result has 2 to
3 elements: the first is the Step_Delay ("h:mm:ss") and the second
element is the Operation code (see STEP command - a decimal
number in the range 0 to 14). If the operation is "GOTO" then a third
element will be returned: a decimal number in the range 1 to 99,
standing for the number of the Step to GOTO.
Syntax
Parameters
Category
stores settings of all the Power Modules.
Syntax
Parameters
Category
XMP 2600 Programming Manual
STEP <int>,<step_delay>,<int>[,<int>]
the number of the Step to be programmed.
the amount of time to delay the Step Operation.
General
format:
h:mm:ss,
mm=minutes and ss=seconds. Step_delay values can
be shortened to "h:mm:" or "h::". Value is limited to
9:59:59.
the operation to be performed by the Step. A
decimal number in the range 0 to 14:
0 = STEP
1 to 10 = RCL 0 to RCL 9
11 = GOTO
12 = OFF
13 = ON
14 = STOP
the forth parameter is required for operation code
"11" (GOTO) only. In this case, it is a decimal
number in the range 1 to 99 representing the Step
number to "GOTO".
System
STEP? <int>
the number of the Step to be reported.
System
STO <int>
a decimal number in the range 0 to 9 specifying the
storage number the XMP 2600 will store the settings
in.
System