Status Reporting Commands And Queries; Synch. Commands And Queries - Xantrex XMP 2600 Programming Manual

Xantrex multiple output power system
Table of Contents

Advertisement

Commands and Queries Reference
Status
*CLS
Reporting
*ESE
Commands
*ESE?
and Queries
*ESR?
*IST?
*PRE
*PRE?
*PSC
*PSC?
*SRE
*SRE?
*STB?
CALDT?
CESE
CESE?
CMASK
CMASK?
CONF?
CSTS?
ERR?
ERR?
OPT?
PEE
PEE?
PER?
PSR?
SRQS?
Synch.
*OPC
Commands
and Queries
*OPC?
*WAI
clears all Event Status Registers.
assign new value to the Standard Event Status Enable Register.
return the value of the Standard Event Status Enable Register.
return the value of the Standard Event Status Register.
return the current value of the Individual Status bit as defined by IEEE
488.1.
assign new value to the Parallel Poll Enable Register.
return the value of the Parallel Poll Enable Register.
controls whether or not the XMP 2600 will clear all the Event Enable
Registers and the 488.2 SRQ and Parallel Poll Enable Registers at Power
On.
return the value of the Power On Status Clear Enable Flag.
assign new value to the Service Request Enable Register
return the value of the Service Request Enable Register.
return the value of the Status Byte Register.
return the Calibration Date of a Power Module.
assign new value to the Channels Event Status Enable Register.
return the value of the Channels Event Status Enable Register.
program the positive and negative edge masks of the Events Filter
Mechanism.
queries the value of the positive and negative edge masks of the Events
Filter Mechanism.
initiates a self-test of a Power Module
return the Power Module Status Structure data.
return the last known Error Code of the XMP 2600 main controller.
return the last know Power Module error code.
return the Options Byte of the Power Module.
assign new value to the Primary Event Status Enable Register.
return the value of the Primary Event Status Enable Register.
return the value of the Primary Event Status Register.
return the value of the Primary Status Register.
return the Power Modules Summary Register.
causes the XMP 2600 to suspend further parsing of commands and
queries until all pending operations have finished. Then, the Operation
Complete (opc) event bit of the Standard Event Status Register will be
set.
causes the XMP 2600 to suspend command parsing until all pending
operations have been finished. Then, the XMP 2600 response to the
Query with: "1".
prevent the XMP 2600 from parsing any further commands or queries
until all pending operations have finished.
XMP 2600 Programming Manual