Xantrex XMP 2600 Programming Manual page 73

Xantrex multiple output power system
Table of Contents

Advertisement

Alphabetical reference
SHUT
SHUT?
SN?
SRQS?
60
defines the optional events that will cause a single, group or global
shutdown.
Syntax
Parameters
Category
returns the current selection of non-fault events that will cause a
single, group or global shutdown. The returned value (in the range 0 to
7) is a sum of individual events categories selections (see SHUT
command above).
Syntax
Parameters
Category
When the Power Supply is turned on or a full reset is performed, the
selection of non-fault events that will cause a single or global shutdown is
cleared.
return the Power Module's Serial Number. The result is a six digit
number.
Syntax
Parameters
Category
return the Power Modules Summary Register. The result is two
decimal numbers. Each bit of the reply represents a channel. A bit
value of "0" means that the Power Module has no enabled status
events. A bit value of "1" means that it has. The reply is a 16-bit value
with its high order byte sent first. The summary bits are cleared and
<rqs> re-calculated.
Syntax
Parameters
Category
XMP 2600 Programming Manual
Commands and Queries Reference
SHUT <int>
the integer is a value in the range 0 to 7, derived
from summing the following event category
selections:
1 – errors reported by the Power Module (not
including error codes 7 and 8).
2 – sense warning.
4 – window warning.
System
SHUT?
none
System
SN? <ch>
the number of the channel to be queried.
System
SRQS?
none
Status
rev. 1.1
Type: Sequential
Type: Sequential
Type: Sequential
Type: Sequential

Advertisement

Table of Contents
loading