Warnings Commands And Queries; Read-Back Queries; Trigger And Sync Commands And Queries - Xantrex XMP 2600 Programming Manual

Xantrex multiple output power system
Table of Contents

Advertisement

Categories
Warnings
IHIGH
Commands
and Queries
IHIGH?
ILOW
ILOW?
VHIGH
VHIGH?
VLOW
VLOW?
WHIGH
WHIGH?
WLOW
WLOW?
Read-Back
IALL?
Queries
ILOAD?
IOUT?
POWER?
VALL?
VLOAD?
VOUT?
Trigger and
*TRG
Sync
ARM
Commands
and Queries
ARM?
SYNC
SYNC?
TRIG
TRIG?
TRIGER
TRIGER
38
program the upper window warning level for the output current of the
Power Module.
return the current settings for the upper window warning level of the
output current of the Power Module.
program the lower window warning level for the output current of the
Power Module.
return the current settings for the lower window warning level of the
output current of the Power Module
program the upper window warning level for the load voltage of the
Power Module.
return the current settings for the upper window warning level of the load
voltage of the Power Module.
program the lower window warning level for the load voltage of the
Power Module.
return the current settings for the lower window warning level of the load
voltage of the Power Module
enable / disable window upper limits checks by the Power Module.
return the state of the Power Module's upper window check enable flag.
enable / disable window lower limits checks by the Power Module.
return the state of the Power Module's lower window check enable flag.
return output current measurements of all operative Power Modules
return output current measurement of the Power Module.
return output current measurement of the Power Module.
return the XMP 2600 delivered output power.
return load voltage measurements of all operative Power Modules.
return load voltage measurement of the Power Module.
return output voltage measurement of the Power Module.
For their internal use (fault and warning detection), the Power Modules
generate a new read-back value every 40 mS.
The Main Controller is updated with new values (available for readback,
10 times a second.
toggles the state of the Global Output Enable Flag
program a Power Module to the Armed state in which further SET and
PROT programming will be stored with no immediate effect of the output
of the Power Module.
return the state of the Power Module.
program the Power Module's Sync Pulse Generation Enable Event.
return the current Sync Pulse Generation Event for the Power Module.
program the Power Module's reaction to a software or hardware trigger.
return the current reaction to trigger for the Power Module.
send a global trigger (to all Power Modules).
send a trigger to the Power Module.
XMP 2600 Programming Manual
Commands and Queries Reference
rev. 1.1

Advertisement

Table of Contents
loading

Table of Contents