4.17.1

Details and parameterization

Principle of operation
The following diagram shows the principle of operation of SLA:
Figure 4-27
Safely-Limited Acceleration (SLA): Principle
Transmission via PROFIsafe
Once SLA has been parameterized and selected, the monitoring results are transmitted in
status words S_ZSW1.8 or S_ZSW2.8.
Note
Response to bus failure
If p9580 ≠ 0 and SLA is active, in the event of a communication failure, the parameterized ESR
reaction only occurs if a STOP with delayed pulse suppression when the bus fails has been
parameterized as the SLA response (p9579 ≥ 10).
Transfer via SIC
Once SLA has been parameterized and selected, the monitoring results are also transmitted in
SIC in status word S_ZSW1B.8. You will find this status word in telegrams 700 and 701.
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
Safety functions integrated in the drive
4.17 SLA
187