Siemens SINUMERIK MC Commissioning Manual page 41

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Figure 2-9
Networking the drive with the SINUMERIK MC
Proceed as follows to establish the connection between the SINUMERIK MC and the
SINAMICS drive:
1. In the working area, open the network view instead of the device view.
2. For a SINAMICS drive, click on the "Not assigned" link.
A selection of possible interfaces is displayed.
3. Select the required interface at the MCU to which you wish to link the drive (e.g.
MCU_NC_1.PLC_1 PROFINET interface_150).
The PROFINET connection is established, and the drive is assigned to the control system.
At the drive, a code for the linked interface of the control system is displayed in the link (e.g.
PLC_1).
4. Save the project to back up the settings.
Result:
You have networked the SINUMERIK MC and the SINAMICS drive with one another.
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
S120 drive created
Fundamentals
2.8 Device configuration
41

Hide quick links:

Advertisement

Table of Contents
loading