Siemens SINUMERIK MC Commissioning Manual page 368

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Data descriptions
10.5 Process data
S_ZSW2 (Extended Functions)
Safety status word 2 (S_ZSW2)
S_ZSW2, input signals
see function diagram [2843].
Table 10-17 Description of safety status word 2 (S_ZSW2)
Byte
Bit
0
0
1
2
3
4
5
6
7
1
0
1
2
3
4
5
6
7
368
Meaning
STO active
SS1 active
SS2 active
SOS active
SLS active
Reserved
SLP active
1
Internal Event
SLA active
Active SLS level bit 0
Active SLS level bit 1
Reserved
SDI positive active
SDI negative active
Reserved
SSM (speed)
1
STO active
0
STO not active
1
SS1 active
0
SS1 not active
1
SS2 active
0
SS2 not active
1
SOS active
0
SOS not active
1
SLS active
0
SLS not active
1
SLP active
0
SLP not active
The status signal "SLP active" is not the same as
the diagnostic signal "SLP active" (r9722.6), but
is the AND logic operation of "SLP active"
(r9722.6) and "safely referenced" (r9722.23).
1
Internal event
0
No internal event
1
SLA active
0
SLA not active
Display of the speed limit for SLS (2 bits)
1
SDI positive active
0
SDI positive not active
1
SDI negative active
0
SDI negative not active
1
SSM (speed below limit value)
0
SSM (speed higher than/equal to limit)
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
Remarks

Hide quick links: