Parameterization; Input / Output Images - Siemens SINUMERIK ONE NCU 1740 Equipment Manual

Hide thumbs Also See for SINUMERIK ONE NCU 1740:
Table of Contents

Advertisement

Connectable components
12.2 PP 72/48D PN
NOTICE
Damage to the module
If the outputs are overloaded, the heat can melt the contacts.
Therefore, for a demand factor of 100%, a max. current of I
Pin 2, must not be exceeded.
Technical data
Table 12-25
Digital outputs
High-level voltage (U
Output current I
Voltage with low level (U
Leakage current at low level
Signal delay time T
Maximum switching frequency
Resistive load
Inductive load
Lamp
1) U
V
: Current operating voltage
CC
I
OUT
Maximum short-circuit current: 4 A (max. 100 μs, V
R
: Maximum internal resistance = 0.4 Ω
ON
2) For a simultaneity factor of 100% (all outputs active)
Incorrect connection causes neither high level nor destruction of the outputs.
12.2.4

Parameterization

12.2.4.1

Input / output images

Input image
The image comprises 2 slots (n, d ≙ start address):
• Slot 1: Digital inputs (DI)
– n+0 ... n+8 (9 byte)
– X222.P3 - .P10 are rapid inputs
• Slot 2: Diagnostics: d+0 .. d+1
124
Electrical specification of the digital outputs
)
H
OUT
)
L
PHL
= V
- I
× R
H_typical
CC
OUT
ON
: Output current
= 0.25 A at X111, X222, X333:
out
min.
Standard
V
- 3 V
1)
CC
-
-
-
-
-
50 μA
-
0.5 ms
-
-
-
-
-
-
= 24 V)
CC
Equipment Manual, 10/2021, A5E51087503B AA
max.
Nominal
V
24 V
CC
250 mA
-
2)
-
Output open
400 μA
-
-
-
100 Hz
-
2 Hz
-
11 Hz
-
NCU 1740

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik sinumerik one ncu 1740

Table of Contents