Siemens SINUMERIK MC Commissioning Manual page 193

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Figure 4-30
When parameterizing a 2-encoder system with Safety Integrated, you must align parameters
p9315 to p9329 with parameters r0401 to r0474.
Note
Assignment of the encoder parameters
Parameters p95xx are assigned to the 1st encoder; parameters p93xx to the 2nd encoder.
Note
Transfer of the values from the encoder commissioning
To accept the values from the parameters filled during the encoder commissioning to the safety
parameterization, set parameter p9700 = 46 (2E hex). This copy function is only possible if you
are connected online with the drive unit.
Table 4-6
Safety parameters
p9315/p9515 SI Motion coarse position value configuration
p9315.0/p9515.0
p9315.1/p9515.1
p9315.2/p9515.2
p9315.16/p9515.16
p9316/p9516 SI Motion encoder configuration, safety functions
p9316.0/p9516.0
p9316.1/p9516.1
p9317/p9517
p9318/p9518
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
Example of a 2-encoder system on a rotary axis
Encoder parameters and corresponding safety parameters for 2-encoder systems
Designation
Up-counter
Encoder CRC, least significant byte first
Redundant coarse position value, most significant
bit left-justified
DRIVE-CLiQ encoder
Motor encoder, rotary/linear
Actual position value, sign change
SI Motion linear scale grid division
SI Motion encoder pulses per revolution
Safety functions integrated in the drive
4.19 Safe actual value acquisition
Encoder parameters
r0474[x].0
r0474[x].1
r0474[x].2
p0404[x].10
p0404[x].0
p0410[x]
p0407
p0408
193