Acceptance test in the SINUMERIK ONE
Commissioning Tool
8.1

Purpose and requirements

The objective of the acceptance test is to check the correct parameterization and mode of
operation of the safety functions and to detect potential configuration errors or to document the
correctness of the configuration.
With the acceptance test, the limit values entered for all activated safety functions must be
exceeded (violated). This allows the correct execution of the function to be checked and
verified.
Unwanted motion due to incorrect parameter changes
Changes to accepted safety functions may lead to faults or to unwanted motion and thus to
serious injuries or death.
● Perform a new acceptance test as soon as changes have been made to any of the safety
● Also create an appropriate acceptance report.
Responsibility for the acceptance test
The machine manufacturer is responsible for carrying out and documenting an acceptance test.
It is not permissible to use the results of the acceptance test for other purposes!
The measured values obtained when executing the acceptance test (e.g. distance or time) and
the system response identified (e.g. initiation of a specific stop) are used to check the
plausibility of the configured safety functions. The values that are measured are typical and are
not worst-case values. They represent the behavior of the machine at the time of measurement.
These measurements cannot be used to derive real values (e.g. maximum distances for over-
travel distances).

Acceptance test in the SINUMERIK ONE Commissioning Tool

The acceptance test for a SINUMERIK MC can be carried out in the SINUMERIK ONE
Commissioning Tool. The precondition to do this is that a SINAMICS S120 drive is being used.
Handling the SINUMERIK ONE Commissioning Tool (Page 3) is derived from SINUMERIK
Operate, which means that there are also no functional differences when compared to the
acceptance test in SINUMERIK Operate.
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
WARNING
functions.