Allocating And Assigning A Profinet Device Name - Siemens SINUMERIK MC Commissioning Manual

Safety integrated (with sinamics s120)
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Commissioning and configuring
6.2 Configuring safety-relevant components
6.2.3

Allocating and assigning a PROFINET device name

Before a PROFINET IO device can be addressed by an I/O controller, it must have a device
name.
Additional general information about PROFINET device names is provided in the TIA Portal
online help.
Precondition
● The PROFINET IO device can be accessed in the network.
Procedure
In order to assign a device name to a PROFINET IO device, proceed as follows:
1. In the device properties, in field "Name", enter the required device name.
2. Click in the network view, right-click on the device and select command "Assign name".
222
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents