6.5.2

Setting software options

Procedure
To set the software options for Safety Integrated, proceed as follows:
1. In the SINUMERIK ONE Commissioning Tool switch to licensing via "MENU SELECT >
Commissioning > Menu forward key > Licenses".
2. Press the "All options" softkey.
3. Set the safety software options required for your particular machine configuration:
Result
The software options were set.
The individual software options to be licensed for the machine can be displayed using softkey
"Missing licenses/options", which you can then order, e.g. through the Siemens Industry Mall.
6.5.3

Activating the safety commissioning mode

Changes to the safety-relevant drive parameterization are only possible if the corresponding
drive is in the Safety Integrated commissioning mode. After parameterization, the Safety
Integrated commissioning mode must be deactivated and the actual checksums must be
transferred into the reference checksums.
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
Software option
Article No.
SINUMERIK XX
6FC5800-0AS60-0YB0
Safety Integrated
/SI logic
SINAMICS S120
6SL3074-0AA10-0AA0
Safety Integrated per
axis of an external
drive
Commissioning and configuring
6.5 Configuring NC and drive-specific safety settings
Explanation
Activate the F-PLC in the SINUMERIK control
system to be able to process the failsafe sensors
and actuators in an F-program.
Each axis that is to be operated with Safety Inte‐
grated Extended and Advanced Functions re‐
quires a license. On the other hand, Basic Func‐
tions do not require a license.
The article number at the left shows a Safety In‐
tegrated Extended Function for CompactFlash
card as example.
When required, you can order additional licen‐
ses. For every license that is ordered, you re‐
ceive a Certificate of Licenses, which you can
then use to obtain licenses from the license da‐
tabase via the "WEB License Manager".
Note:
Only for SINAMICS are the Safety Integrated
Functions SP, SLP and SCA classified as Ad‐
vanced Functions. They require a different type
of license than the Extended Functions.