6.1.3. Multiple simultaneous connections

The matrix allows simultaneous remote control over multiple interfaces. Ethernet and
Serial connections can be used at the same time. However, only 1 connection can be
used with the Lightware Device Controller (LDC) via Ethernet por.

6.1.4. Serial port settings

UMX4x4-Pro2 uses RS-232 communication port. The device uses standard RS-232
interface with the following default settings:
The serial port baud rate can be changed on the front panel LCD menu (see section
on page 37) or remotely by protocol command (see sections 8.6.4,

6.1.5. IP settings

The Ethernet port can be configured on the front panel LCD menu, remotely through the
Lightware Device Controller (LDC) software, or the built-in website.
The factory default IP settings or DHCP mode can be activated quickly through front
panel shortcut buttons. To reset the IP configuration perform the following:
Resetting the IP address
Reset to factory default IP configuration or to DHCP mode with front panel buttons.
Step 1. Switch the router to TAKE mode if used previously in AUTOTAKE mode by
Step 2. Press and hold down the Control Lock button for 3 seconds (Control Lock button
Step 3. Press and keep pressed the Output Lock button.
Step 4. Press and release the
Step 5. A beep can be heard and a light sequence will occur to confirm the command.
Step 6. After about three seconds another beep can be heard and a reverse light
Step 7. Press Control Lock button for 3 seconds (red light will go off) to back to the
Step 8. Wait about 5 seconds before connecting the router via Ethernet.

6.1.6. Control protocols

Matrix routers can be controlled with multiple control protocols. Lightware routers have a
special protocol, but to interoperate with third party devices, a secondary protocol is also
provided.
Section 6. Remote operation
57600 Baud, 8 data bit, 1 stop bit, no parity
pressing TAKE button for 3 seconds (light will go off).
lights in up red continuously).
a)
Load Preset button to set the factory default IP settings
IP address:
port number:
subnet mask:
gateway:
b)
Save Preset button to set DHCP enabled
IP address:
port number:
subnet mask:
gateway:
(Save Preset, Load Preset and Take/Auto buttons will light up one after the other)
sequence will occur to indicate that, the settings have been completed.
(Take/Auto, Load Preset and Save Preset buttons will light up one after the other)
normal operation.
192.168.254.254
10001
255.255.0.0
0.0.0.0
Acquired with DHCP
unchanged
Get from DHCP server
Get from DHCP server