100 |
remove it (n. 15) and the pilot nozzle (n. 16).
- Replace the pilot nozzle with the correct nozzle,
consulting the "BURNERS" table.
- After replacing the pilot nozzle, retighten the nut
pressing the biconical coupling (no. 14) with the
relevant biconical coupling (no. 15).
Regulation of the pilot light (fig. 11C)
15 ,20 and 22 L models
Use a 7 mm hexagonal spanner to adjust the pilot light (1).
The nozzle is correctly set when the flame surrounds the
thermocouple. When using LPG, the adjusting screw (1)
should be completely tightened.
APPLIANCE SAFETY SYSTEMS
Safety valve: a thermocouple valve stops the gas flow from
reaching the main burner in the event of the pilot flame
going out.
To restore the operation, repeat the operations relevant to
igniting the pilot device.
Safety thermostat: stops the gas flow in the event of
EN
serious anomalies. it is reactivated manually and, to restore
it, it is necessary to unscrew the nut (no. 7) (fig. 7-8). If the
safety thermostat starts up, call the technical assistance.
The FA models are equipped with electric basket lifter and
oil circulation pump with integrated fuses in the electrical
connection box. Please call Technical Support in the event
of a failure of the oil circulation pump or the basket lifter.

MAINTENANCE

The construction of the appliances is carried out in a
way where a few maintenance operations are necessary.
Because of this, we recommend that the user subscribe to
the assistance agreement to have the equipment checked
at least once a year by the specialised personnel of our
assistance service or by a specialized technician.
Warnings
It is necessary to periodically check the stuffing box system
of the deep fryers. The stuffing boxes on deep fryers
should be tight so as to avoid any oil leakage which in the
long run could cause problems.

REPLACING THE COMPONENTS

USE ONLY ORIGINAL SPARE PARTS SUPPLIED BY THE
MANUFACTURER. The parts must be replaced solely by
authorized personnel!
For a few models, it is sufficient to remove the panel by
unscrewing the screws in view on the lower edge or in the
front to have access to those parts to be replaced; for the
other models, it is sufficient to open the lower door.
ATTENTION: empty the tank before removing the
panel and replace the components.
Gas valve: all connections are visible. With the means of
suitable wrenches, unscrew the connections at the input
and output of the gas, pilot flame and thermocouple.
(SPARE PARTS)
MOD.
N°:
Unscrew the two fixing screws on the side and replace
Qn
them. Insert the bulb properly .
V
kW:
Hz: 50/60
Safety thermostat: disconnect the thermocouple Faston
terminal. Unscrew the covering nut, unscrew the fixing
nut and replace it. Make sure that the faston terminals are
connected properly. Make sure that the thermostat bulb is
properly inserted.
Burner: the burner is fixed with two visible screws and
with a nut to the pipe. Unscrew it, replace it and screw it
in properly.
Thermocouple – igniter plug: to replace these two
components more easily, unscrew the two screws that
fix the pilot flame support. Replace them and screw the
screws back in.
After replacing, reassemble the control panel and the
relevant parties in the proper order.
WARNING
Every time a replacement involving gas input parts is
made, recheck all the functions and test for leakage.

USE INSTRUCTIONS

PUT INTO SERVICE
The appliance is strictly for professional use and must be
used by qualified personnel.
We recommend that the user make sure that the
installation was properly done. The manufacturer is not
responsible for damages due to an incorrect installation,
bad maintenance or incorrect use.
Before
operating,
CAREFULLY
INSTRUCTIONS WITHIN THIS MANUAL; pay particular
attention to the regulations relevant to the safety devices.
Close all gas supply cocks after use and, above all, during
maintenance and repair operations. Carefully follow the
cooking instructions for at least the initial period up to
when practice and experience will help you to personally
choose a cooking time and temperature. Before switching
on the burner, carefully wash the components in contact
with the cooking oil, as explained in the paragraph
devoted to cleaning, and then fill up the tank with oil up to
the tank reference notch (level) after having checked that
the draining tap is closed.
IGNITION
The burners are supplied by a thermostatic safety valve.
Pilot burner ignition (GL8..., GL10...) (fig. 7)
Press the (
) button (3), wait for the air to come out from
the tubes and press the piezoelectric button (2) several
times. Look though the hole on the panel to see if the pilot
flame is lit. Keep the button (3) pressed for a few seconds
and then release it. If the pilot flame switches off, repeat
the operation.
IPX2