debounce
tHe debounce Parameter
The
DEBOUnCE
parameter is used to combat
any trigger bounce that might occur in the
Ego10 and can be set between level 1 and
level 9 in one level increments.
> leVel 9: level 9 providing the most
filtering (least 'bouncy').
> leVel1: level 1 providing the least
filtering (most 'bouncy').
> cancel: Cancel editing and leave the parameter
unchanged.
emPtY
tHe breecH emPtY time
Parameter
in order for the bbSS to function correctly
it must first detect that the bolt is fully
retracted and the breech is empty, and then
detect that a paintball is loaded into the
breech before the Ego10 is allowed to fire.
Slots or holes in some third party bolts can
fool the bbSS and so this parameter is used
to specify a minimum time that the breech
must be empty. The parameter can be set between 1.0 and
20.0ms in 0.5ms increments.
full
tHe breecH full time Parameter
Tumbling paintballs can take time to
settle in the breech before they can be
successfully fired. This parameter is used
to set the amount of time that a paintball
has to be in the breech before the Ego10 is
allowed to fire. This parameter can be set
between 1.0 and 20 milliseconds in 0.5ms
increments.
Pull tm
tHe triGGer Pull time Parameter
The
pULL tM
parameter is used to set the
minimum amount of time that the trigger
must be pulled before it is recognised as a
valid trigger pull. This parameter can be set
between 3.0 and 20.0 milliseconds in 0.5
increments.
release tm
tHe triGGer release
time Parameter
The
rELEaSE tM
minimum amount of time that the trigger
must be released before it is recognised as a
valid trigger release. This parameter can be
set between 3.0 and 25.0 milliseconds in 0.1
millisecond increments.
Pull Pt
tHe triGGer Pull Point
Parameter
The
pULL pt
parameter is only available if
OPTO
has been selected in the
menu.
defines the point at which
pULL pt
the trigger is considered pulled and is
adjustable between 51% and 99% in 1%
increments.
release Pt
tHe triGGer release Point
Parameter
The
parameter is only available
rELEaSE pt
if OPTO has been selected in the
menu.
rELEaSE pt
the trigger is considered released and is
adjustable between 1% and 49% in 1%
increments.
parameter is used to set the
HarDWarE
HarDWarE
defines the point at which
QuicK Guide
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR EGO10
MENU TREE
ADVANCED SET-UP
ADVANCED SET-UP
MAINTENANCE
FAULT FINDING
SERVICE CENTERS
PARTS LIST
SPARES & ACCESSORIES
INDEX
41.

Advertisement

loading
Need help?

Need help?

Do you have a question about the EGO TEN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ego 10