Goodrive300-21 integrated machine for air compressor
Function
Name
code
selection
P05.11
Digital filter time
Close delay time of S1
P05.14
terminal
Turn-off delay time of
P05.15
S1 terminal
Close delay time of S2
P05.16
terminal
Turn-off delay time of
P05.17
S2 terminal
Close delay time of S3
P05.18
terminal
Turn-off delay time of
P05.19
S3 terminal
Close delay time of S4
P05.20
terminal
Turn-off delay time of
P05.21
S4 terminal
Close delay time of S5
P05.22
terminal
Turn-off delay time of
P05.23
S5 terminal
P05.32 Lower limit value of P1 0.00V–P05.34
Corresponding setting
P05.33
of P1 lower limit
P05.34 Upper limit value of P1 P05.32–10.00V
Corresponding setting
P05.35
of P1 upper limit
Detailed instruction
input terminals.
When the bit is set to 0, input terminal is positive
polarity;
When the bit is set to 1, input terminal is negative
polarity
BIT8
BIT7
Reserved Reserved Reserved Reserved
BIT4
BIT3
BIT2
S5
S4
Setting range: 0x000–0x1FF
0.000–1.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
0.000–50.000s
-100.0%–100.0%
-100.0%–100.0%
-
-
31
BIT6
BIT5
BIT1
BIT0
S3
S2
Function instruction
Default
Modify
value
S1
○
0.200s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
2.00V
○
0.0%
○
10.00V
○
100.0%