SLM-3650 Satellite Modem
Theory of Operation
4.1.2
Remote Baud Rate
The remote communications baud rate and parity are programmed by the front panel
control in the Utility System menu (refer to
parity are maintained indefinitely in RAM on the M&C module. The parity bits can be
set to EVEN or ODD. The available baud rate are listed below:
•
150
•
300
•
600
•
1200
•
2400
•
4800
•
9600
•
19200
4.1.3
Remote Address
To communicate with the established remote communications protocol, configure each
modem for one address between 1 and 255. Each modem on a common remote
communications link (EIA-485) must have a distinct address. Use the front panel control
in the Function Select: Utility: System menu
An EIA-485/EIA-232 communications link remotely controls and monitors all modem
functions. Use the 2- or 4-wire, half-duplex EIA-485 interface to connect between two or
more modems and switches on a common communications link. Use the EIA-232
interface to communicate with a single modem.
Note: Address 0 is reserved as a global address which simultaneously addresses all
devices on a given communications link.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Chapter
3). The programmed baud rate and
(Chapter
3) to program the address.
4–4
Revision 3
MN/SLM3650.IOM