SLM-3650 Satellite Modem
Options
A.1.4
Asynchronous Interface/AUPC
Note: If required, refer to Section A.3 for installation of the overhead interface PCB.
The asynchronous (ASYNC) interface option provides the interface for terrestrial data
and a single ASYNC overhead channel. Typically used for earth-station-to-earth-station
communication, the overhead channel is MUXed onto the data and transmitted at an
overhead rate of 16/15 of the main channel. The AUPC feature works with the ASYNC
option to allow remote communication between a local modem and a remote modem.
Refer to Figure A-5 for a modem block diagram with the ASYNC/AUPC interface
option.
G.703, EIA-422, or V.35 interfaces are available for terrestrial data input and output.
These interfaces can be selected via the front panel.
EIA-485 or EIA-232 interfaces are available for ASYNC channel input and output. These
interfaces can also be selected from the front panel. Fixed 1/15 overhead is added to the
data when an ASYNC channel is being used. With the ASYNC channel enabled, the
terrestrial data rate can be from 8 to 2048 kbps. The ASYNC channel I/O protocol can be
as follows:
Note: Certain combinations of baud rate, data rate, parity, and stop bits will limit the
maximum baud rate allowed for continuous throughput based on terrestrial data
rate.
ASYNC overhead is a 1/15 rate overhead channel composed of the following:
Framing information
EIA-232 or EIA-485 data
Valid data flags
AUPC information (if installed)
Parity bits
The rate of asynchronous data transfers may be selected by the operator, with the
maximum rate available limited to 1.875
Note: The asynchronous overhead structure is a Comtech EF Data standard, and is not
compatible with IBS or IDR overhead formats.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Baud
110 to 38400
Data Bits
5 to 8
Parity
odd, even, or none
Stop Bits
1 or 2
of the synchronous data rate.
%