SLM-3650 Satellite Modem
Operation
3.4.14.4
Function Select: Utility: System
Refer to Figure 3-20.
TIME:
HH:MM:SS AM/PM
DATE:
MM/DD/YYYY
REMOTE BAUD RATE
X
PARITY
REMOTE ADDRESS
REMOTE TYPE
OPERATION MODE
YEAR DISPLAY
TEST MODE STATUS
LAMP TEST ??
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Time of day and date display/set function.
The current time and date in the modem's memory are displayed when selected. To change
the modem time and/or date, press [ENTER]. Press [←] or [→] to position the cursor over
the parameter to be changed. Press [↑] or [↓] to change the parameter. Once the
parameters are displayed as desired, press [ENTER] to set the time and date.
The parity and baud rate settings of the modem are displayed.
To change the modem baud rate and/or parity, press [ENTER]. Press [←] or [→] to
position the cursor over the parameter to be changed. Press [↑] or [↓] to change the
parameter. Once the parameters are displayed as desired, press [ENTER] to set the baud
rate and parity. The parity can be set to EVEN, ODD, or NONE. The baud rate can be set
from 110 to 19200 bit/s.
The current modem address is displayed (1 to 255).
To change the remote address, press [ENTER]. Press [↑] or [↓] to make the selection.
Press [ENTER] to execute the change.
Select EIA-485 (2-Wire), EIA-485 (4-Wire), or EIA-232.
Programs the modem for DUPLEX, TRANSMIT ONLY, or RECEIVE ONLY operation.
Upon entry, the operational status may be changed. Press [↑] or [↓] to make the selection.
Press [ENTER] to execute the change.
Conditional: When TX ONLY or RX ONLY are selected, the appropriate faults are masked
from the Faults and Stored Faults menus.
Displays the year in either 2-digits or 4-digits.
To change the remote address, press [ENTER]. Press [↑] or [↓] to make the selection.
Press [ENTER] to execute the change.
Test mode status indicator. The following modem test points are listed and display a "+"
when a test mode is active:
RS CORR OFF
INTRFC LOOPBACK
B-BAND LOOPBACK
RF LOOPBACK
IF LOOPBACK
CARRIER MODE
RX 2047 Pattern
TX 2047 Pattern
To view the test modes, press [ENTER]. Press [↑] or [↓] to make the selection.
Lamp test function. Press [ENTER] to turn the front panel indicators on for three seconds.
3–64