Comtech EF Data SLM-3650 Installation And Operation Manual page 240

Satellite modem
Table of Contents

Advertisement

SLM-3650 Satellite Modem
Options
A.1.3.2
Theory of Operation
The main features of the D&I option are as follows:
Data interface
Transmit MUX
Receive DEMUX
ESC
Backward alarm
A.1.3.2.1
Data Interference
Data interface contains transformer
parameters and dejitter. This is compatible with AT&T Digital Speech Interpolation
(DSI) service. Data inputs and outputs named are listed below:
Data Inputs
Data Outputs
The system is frequently used with the drop receive data output signal (DRD
looped to feed the insert send data input signal (ISD-A, -B). This is accomplished at the
far end of any redundancy switching in order to allow transmit and receive chains to be
switched independently. The zero substitution codes (Alternate Mark Inversion [AMI],
B8ZS, and HDB3) are user
A data loopback function on the insert data is available in this section. This enables the
user to determine that the T1 or E1 data parameters correctly match those of this
interface. The drop data is always hard
A.1.3.2.2
Transmitted MUX
The data stream is transmit MUX with a 1/15 overhead channel and the resultant
information rates are interfaced to the Mod/Demod/Coder sections of the modem. A
phase-locked loop generates the output clock (with overhead), using the input clock as a
reference. The input clock is normally the recovered clock from the data interface. If a
valid input signal is not present, the interface falls back to a 10
generated in the modem, and will transmit a valid IESS-308 framing pattern. If this
occurs, the link will remain open at the far end and a fault will be signaled.
The transmit data will be replaced with an all 1s pattern (AIS) in the event of certain
failures, in accordance with IESS-308.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
balanced data interfaces that support CCITT G.703
-
Drop send data input A and B (DSD-A and DSD-B)
Insert send data input A and B (ISD-A and ISD-B)
Drop receive data output A and B (DRD-A and DRD-B)
Insert receive data output A and B (IRD-A and IRD-B)
selectable during configuration.
-
wired into loopback.
-
A–12
Revision 3
MN/SLM3650.IOM
A, -B)
-
accuracy reference clock