Determine Which Drive Is Faulty; Remove A Drive - Oracle SPARC T8-2 Service Manual

Table of Contents

Advertisement

"Remove a Drive" on page 65
"Install a Drive" on page 70
"Remove a Drive Filler" on page 69
"Install a Drive Filler" on page 72
"Verify a Drive" on page 73

Determine Which Drive Is Faulty

The following LEDs are lit when a drive fault is detected:
System Service Required LEDs on the front and rear panels.
Service Required LED on the faulty drive.
1.
Check to see if any System Service Required LEDs are lit or flashing.
See
"Interpreting LEDs" on page
2.
From the front of the server, check the drive LEDs to identify the faulty drive.
The amber Service Required LED is lit on the drive that needs to be replaced.
See
"Drive LEDs" on page
3.
Remove the faulty drive.
See
"Remove a Drive" on page
Related Information
"Drive LEDs" on page 64
"Remove a Drive" on page 65
"Install a Drive" on page 70
"Verify a Drive" on page 73
"Detecting and Managing Faults" on page 27

Remove a Drive

This is a hot-service procedure that can be performed by a customer while the server is running.
This procedure requires that you handle components that are sensitive to ESD which
Caution -
can cause server components to fail.
33.
64.
65.
Determine Which Drive Is Faulty
Servicing Drives
65