Oracle SPARC T8-2 Service Manual page 74

Table of Contents

Advertisement

Verify a Drive
# cfgadm -c configure c0::sd1
Replace c0::sd1 with the drive name for your configuration.
Verify that the blue Ready to Remove LED is no longer lit on the drive that you
4.
installed.
See
"Determine Which Drive Is Faulty" on page
5.
At the Oracle Solaris prompt, list all drives in the device tree, including any
drives that are not configured.
# cfgadm -al
The replacement drive is now listed as configured, as shown in the following example.
Ap_Id            Type         Receptacle   Occupant      Condition
c0               scsi-bus     connected    configured    unknown
c0::dsk/c1t0d0   disk         connected    configured    unknown
c0::dsk/c1t1d0   disk         connected    configured    unknown
usb0/1           unknown      empty        unconfigured  ok
usb0/2           unknown      empty        unconfigured  ok
...
6.
Perform one of the following tasks based on your verification results:
If the previous steps did not verify the drive, see
Faults" on page
If the previous steps indicate that the drive is functioning properly, perform
the tasks required to configure the drive. These tasks are covered in the
Oracle Solaris OS administration documentation.
For additional drive verification, you can run Oracle VTS. Refer to the Oracle VTS
documentation for details. Refer to http://docs.oracle.com/cd/E19719-01/index.html.
Related Information
"Determine Which Drive Is Faulty" on page 65
"Remove a Drive" on page 65
"Install a Drive" on page 70
74
SPARC T8-2 Server Service Manual • June 2019