Oracle SPARC T8-2 Service Manual page 113

Table of Contents

Advertisement

d.
Unpack and install the new battery.
Press the new battery into the battery holder with the positive side (+) facing away from
the metal tab that holds it in place.
e.
Install memory risers
f.
Return the Server to
Reset the system clock.
3.
a.
Use the Oracle ILOM clock command to reset the system clock.
The following example sets the date to August 22, 2016, and the timezone to EDT.
-> set /SP/clock datetime=081221302016 timezone=EDT
Set 'datetime' to '081221302016'
set 'timezone' to 'EDT'
-> show -d properties /SP/clock
Properties
datetime = Mon Aug 22 13:20:16 2016
timezone = EDT (EST5EDT)
uptime = 2 days 19:56:49
usentpserver = disabled
b.
If the SP policy HOST_AUTO_POWER_ON was enabled before you replaced the
battery, you must re-enable it.
-> set /SP/policy HOST_AUTO_POWER_ON=enabled
c.
If the /SP/clock usentpserver property was enabled before you replaced the
battery, you must re-enable it.
-> set /SP/clock usentpserver=enabled
4.
Verify the battery.
-> show /SYS/MB/BAT
Related Information
"Identify Faulted Components" on page 29
CM0/MR0, CM0/MR2 and CM0/MR3.
Operation.
Replace the Battery
Servicing the Battery
113