Determine Which Drive Is Faulty
You must determine which drive is faulty before you replace it.
1.
Check to see if any System Service Required LEDs are lit or flashing.
See
"Interpreting LEDs" on page
2.
Visually inspect the drive to see if any of its status LEDs are lit or flashing.
See
"Drive LEDs" on page
If the drive is faulty, replace it. See
3.
If you are unable to identify the faulty drive, seek further information.
See
"Detecting and Managing Faults" on page
Remove the faulty drive.
4.
See
"Remove a Drive or Drive Filler" on page
Related Information
"Drive LEDs" on page 62
■
"Remove a Drive or Drive Filler" on page 63
■
"Install a Drive or Drive Filler" on page 68
■
"Verify a Drive" on page 69
■
"Detecting and Managing Faults" on page 23
■
Remove a Drive or Drive Filler
You can perform this procedure while the server is running. See
Categories" on page 45
To hot-service a drive, you must first take it offline. This action prevents applications from
accessing the drive and removes software links to it.
29.
62.
"Remove a Drive or Drive Filler" on page
23.
63.
for more information about hot-service procedures.
Determine Which Drive Is Faulty
63.
"Component Service
Servicing Drives
63