d.
Attach the screw to fasten the PS backplane cover in place.
7.
Reinstall the air divider by sliding it into the chassis.
8.
Reinstall the memory risers.
See
"Install a Memory Riser" on page
9.
Push the power supplies all the way back into the chassis.
See
"Install a Power Supply" on page
10.
Return the server to operation.
See
"Returning the Server to Operation" on page
Related Information
"Remove the PS Backplane" on page 165
■
"Verify the PS Backplane" on page 169
■
Verify the PS Backplane
1.
At the Oracle ILOM prompt, start the fault management shell.
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
faultmgmtsp>
2.
Type fmadm faulty to check for faults.
If faults are reported, see
■
If no faults are reported, then the PS backplane has been replaced successfully.
■
Related Information
"Remove the PS Backplane" on page 165
■
"Install the PS Backplane" on page 167
■
104.
86.
171.
"Detecting and Managing Faults" on page 27
Verify the PS Backplane
.
Servicing the PS Backplane
169