Oracle SPARC T8-2 Service Manual page 108

Table of Contents

Advertisement

Enable and Verify a DIMM
0:0:0>POST:
0:0:0>Master set ACK for vbsc runpost command and spin...
Note -
at the OpenBoot prompt (ok) go to the next step.
f.
If the server remains at the OpenBoot prompt, type boot.
Return the virtual keyswitch to Normal mode.
g.
-> set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
h.
Switch to the system console and type:
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in
Faulted Components" on page
4.
Switch to the Oracle ILOM command shell.
Type:
5.
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
If the show faulty command reports a fault with a UUID go to the next step. If show faulty
does not report a fault with a UUID, you are done with the verification process.
6.
Switch to the system console and type the fmadm repair command with the UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show faulty
command.
# fmadm repair 7c7efb20-3333-e2d7-b8ea-986b3e9dbaa9
108
SPARC T8-2 Server Service Manual • June 2019
Return to VBSC.
The server might boot automatically at this point. If so, go to step f. If the server remains
| Property
| fru
| timestamp
| sunw-msg-id
|
| uuid
|
| timestamp
|
29.
| Value
| /SYS/MB/CMP0/CMP/MR0/BOB1/CH0/DIMM
| Nov 18 16:02:56
| SPSUN4V-8000-CQ
|
| 7c7efb20-3333-e2d7-b8ea-986b3e9dbaa9
|
| Nov 18 16:02:56
|
"Identify