Oracle SPARC T8-2 Service Manual page 112

Table of Contents

Advertisement

Replace the Battery
c.
Check the NTP policy for the /SP/clock.
-> show /SP/clock usentpserver
d.
If enabled, set the property to disabled.
-> set /SP/clock usentpserver=disabled
Replace the battery.
2.
Replacing the battery is a cold-service procedure. The server must be
and power cables disconnected before performing this procedure.
a.
Prepare the server for
b.
Remove memory risers
Remove the old battery.
c.
Gently push the battery toward the memory risers to release it from the retention clip.
112
SPARC T8-2 Server Service Manual • June 2019
Properties:
usentpserver = enabled
service.
CM0/MR0, CM0/MR2 and CM0/MR3.