Rockwell Automation Allen-Bradley DriveLogix 5730 User Manual page 165

Or powerflex 700s drives with phase ii control
Table of Contents

Advertisement

1.
Right click on the 1788-DNBO and choose Properties.
TIP: Configuration changes made to the adapter or any of its I/O modules
with RSNetWorx will not be saved or downloaded to the adapter once the
adapter is configured in a scanner's scanlist.
To make configuration changes, the controller must be placed into the
Program mode and the adapter must be temporarily removed from the
scanner's scanlist.
Setting Up the 1788-DNBO DeviceNet Scanner Scanlist
2.
Click the Scanlist tab, then click Upload when prompted. The area on
the left is called "Available Devices" and the area on the right is called
"Scanlist". The 1769-ADN adapter should be on the left.
Communicating with Devices on an DeviceNet Link