Download Print this page
Rockwell Automation Allen-Bradley Compact GuardLogix 5380 SIL 2 Installation Instructions Manual
Rockwell Automation Allen-Bradley Compact GuardLogix 5380 SIL 2 Installation Instructions Manual

Rockwell Automation Allen-Bradley Compact GuardLogix 5380 SIL 2 Installation Instructions Manual

Advertisement

Quick Links

Installation Instructions
Original Instructions
Compact GuardLogix 5380 SIL 2 Controllers
Catalog Numbers 5069-L306ERS2, 5069-L306ERMS2,
5069-L310ERS2, 5069-L310ERMS2,
5069-L320ERS2, 5069-L320ERS2K,
5069-L320ERMS2, 5069-L320ERMS2K,
5069-L330ERS2, 5069-L330ERS2K,
5069-L330ERMS2, 5069-L330ERMS2K,
5069-L340ERS2, 5069-L340ERMS2,
5069-L350ERS2, 5069-L350ERS2K,
5069-L350ERMS2, 5069-L350ERMS2K,
5069-L380ERS2, 5069-L380ERMS2,
5069-L3100ERS2, 5069-L3100ERMS2
Topic
The Compact GuardLogix® 5380 controller is a programmable automation controller with integrated safety. Compact GuardLogix 5380 SIL 2 controllers are for use in
functional safety applications up to and including Safety Integrity Level (SIL) 2 and Performance Level (d).
Use the Studio 5000 Logix Designer® application to configure the Compact GuardLogix 5380 controllers.
For more information on how to use the controller after you install it, including safety application requirements, see the publications that are listed in the
Additional Resources on page
12.
Summary of Changes
This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.
Topic
Added wiring diagrams for the MOD power and SA power RTBs
Page
5
5
5
6
7
9
9
9
10
10
11
12
Page
7, 8

Advertisement

loading
Need help?

Need help?

Do you have a question about the Allen-Bradley Compact GuardLogix 5380 SIL 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rockwell Automation Allen-Bradley Compact GuardLogix 5380 SIL 2

  • Page 1: Table Of Contents

    Installation Instructions Original Instructions Compact GuardLogix 5380 SIL 2 Controllers Catalog Numbers 5069-L306ERS2, 5069-L306ERMS2, 5069-L310ERS2, 5069-L310ERMS2, 5069-L320ERS2, 5069-L320ERS2K, 5069-L320ERMS2, 5069-L320ERMS2K, 5069-L330ERS2, 5069-L330ERS2K, 5069-L330ERMS2, 5069-L330ERMS2K, 5069-L340ERS2, 5069-L340ERMS2, 5069-L350ERS2, 5069-L350ERS2K, 5069-L350ERMS2, 5069-L350ERMS2K, 5069-L380ERS2, 5069-L380ERMS2, 5069-L3100ERS2, 5069-L3100ERMS2 Topic Page About the Controller Dimensions Before You Begin Install the Controller onto the DIN Rail Wire External Power Supplies to the Controller...
  • Page 2 Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant, dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt. Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 3 In addition to this publication, see the following: • Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements. • NEMA 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures. Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 4 Any illustrations, charts, sample programs, and layout examples that are shown in this publication are intended solely for the purposes of example. Since there are many variables and requirements that are associated with any particular installation, Rockwell Automation does not assume responsibility or liability for actual use that is based upon the examples that are shown in this publication.
  • Page 5: About The Controller

    DIN rail. Failure to do so could result in equipment Side View damage or injury from electric shock. 136.81 mm (5.39 in.) 130.31 mm (5.13 in.) Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 6: Ground Considerations

    SA power current draw in the system, including the combined inrush current requirements for all connected modules. IMPORTANT Compact GuardLogix 5380 controllers do not have an embedded power supply that powers the system. Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 7: Wire External Power Supplies To The Controller

    Connect the 24V DC(—) wire from the external power supply to the first MOD Power RTB Wiring Diagram MOD(—) terminal. 5069-RTB4-SCREW RTB 5069-RTB4-SPRING RTB 5069-RTB4-SPRING RTB 5069-RTB4-SCREW RTB 24V (+) 24V (+) 24V (+) 24V (+) 24V (-) 24V (-) 24V (-) 24V (-) Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 8 Earth Ground terminal that provides a low impedance path between electrical circuits and earth for functional purposes and provides noise immunity improvement. This connection must be made for functional purposes. Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 9: Install The End Cap

    Align the end cap with the interlocking pieces on the controller. Push the end cap toward the DIN rail until it locks into place. A Top interlocking pieces B End cap C Bottom interlocking pieces Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 10: Connect The Controller To An Ethernet/Ip Network

    Pull the controller away from the DIN rail. To replace the controller, see Install the Controller onto the DIN Rail on page Apply MOD power and, if necessary, SA power to the system. Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 11: Specifications

    (2) Maximum level of MOD or SA power current that the controller can pass through to the next module in the system. The specific level of current passed through varies based on system configuration. Rockwell Automation Publication 5069-IN014G-EN-P - September 2024...
  • Page 12: Additional Resources

    Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, Compact 5000, expanding human possibility, GuardLogix, Logix 5000, Rockwell Automation, RSLinx, and Studio 5000 Logix Designer are trademarks of Rockwell Automation, Inc.