Main Diagnostics Screen; Diagnostic Main Menu Description; Flow Data Menu - Siemens SITRANS FUS1020 Manual

Nema-4/ip 65 clamp-on transit-time flowmeter
Table of Contents

Advertisement

Section 7
DIAGNOSTIC DATA MENU STRUCTURE (continued)
Diagnostic Data
7.1

MAIN DIAGNOSTICS SCREEN

This is the main Diagnostics Data screen. It provides menus that show Flow, Application, Liquid, Site
Setup information. The Test Facilities menu provides test/control functions to optimize operation, ana-
lyze application conditions and to recover system operation.
Flow Data
Application Info
Liquid Data
Site Setup Data
Test Facilities
Print Site Setup
Date Site Created
7.2

FLOW DATA MENU

This menu provides a "live" display of all flow-related output data.
Test Facilities
Print Site Setup
Date Site Created
Siemens
2 Channel
Real-time flow-related data
Flow Data
Application Data
Liquid Data
Site Setup Data
Test Facilities
Print Site Setup
Data Site Created
Diagnostic Data

DIAGNOSTIC MAIN MENU DESCRIPTION

This menu shows flow rate, total & alarm data; adjustable flow limits.
This menu shows current meter operating status.
This menu shows current Reynolds #.
This menu shows current transducer setup data and signal status.
This menu provides system test and recovery routines.
This Menu cell allows you to send an ASCII dump of the current Site
Data to a RS-232 port device (e.g. a printer or laptop computer).
This menu cell shows date and time when the current site was created.
Siemens
2 Channel
Current Flow Rate and Units
Flow GAL/MIN
Flow Vel F/S
Total KGAL
Vs m/s
Signal mV
Valc %
Vaer %
Alarm Status
AnCal GAL/MIN
HiFlow GAL/MIN
LoFlow GAL/MIN
Flow Data
Tx Dn
Fixed ALC
Tx Up Fixed ALC
Tx Dn Fixed ALC
No/Yes
xx.xx.xx xx.xx.xx
[1]
Channel 1
No
09.02.98 13.24.01
[1]
Channel 1
-2.26
0.0000
1273.21
44
57
0
---R-----
0.0000
1576.8
-1576.8
7-2
1020NFM-1D

Advertisement

Table of Contents
loading