Commands; Command List - YOKOGAWA TA220 User Manual

Digital jitter meter
Table of Contents

Advertisement

10.2 Commands

10.2.1

Command List

Command
CALCulation Group
:CALCulation:AVERage?
:CALCulation:CONStt?
:CALCulation:DEViation?
:CALCulation:DEVT?
:CALCulation:FLUTter?
:CALCulation:JITTer?
:CALCulation:LEVel?
:CALCulation:MAXimum?
:CALCulation:MINimum?
:CALCulation:PTOPeak?
:CALCulation:SDEViation?
:CALCulation:SNUMber?
COMMunicate Group
:COMMunicate?
:COMMunicate:HEADer
:COMMUNICATE:LOCKout
:COMMunicate:REMote
:COMMunicate:VERBose
:COMMUNICATE:WAIT
:COMMunicate:WAIT?
DCOut Group
:DCOut?
:DCOut:CYCLe
:DCOut:COEFficient
:DCOut:JITTer:PERCent
:DCOut:JUDGe:PERCent
:DCOut:JUDGe:RESult?
:DCOut:MODE
DISPlay Group
:DISPlay?
:DISPlay:MEASure
:DISPlay:PARameter:AVERage
:DISPlay:PARameter:CONStt
:DISPlay:PARameter:DELay
:DISPlay:PARameter:EQ
:DISPlay:PARameter:JITTer
:DISPlay:PARameter:LSNum
:DISPlay:PARameter:SDEViation Sets the σ display or queries the current setting.
:DISPlay:PARameter:USNum
:DISPlay:SCALe
:DISPlat:SECond
:DISPlay:STATe
HHIStogram Group
:HHIStogram?
:HHIStogram:MARKer?
:HHIStogram:MARKer:LEFT
:HHIStogram:MARKer:RIGHt
IM 704610-01E
Function
Queries the average value.
Queries time width T.
Queries the deviation.
Queries the deviation/T value.
Queries the σ/AVE (flutter) value.
Queries the σ/T (jitter ratio).
Queries the level.
Queries the maximum value.
Queries the minimum value.
Queries the P-P value.
Queries the jitter (σ).
Queries the number of samples of the statistical calculation.
Queries all settings related to communication.
Sets whether or not to add a header to the response data, or queries the setting. 10-14
Sets/queries the local lockout setting.
Switches between remote and local mode.
Sets abbreviated or verbose format for response data, or queries the setting.
Wait for specified extended event to occur.
Creates response data upon occurrence of the specified extended event.
Queries all settings related to DC output.
Sets the DC output average coefficient or queries the current setting.
Sets the DC output correction coefficient or queries the current setting.
Sets the upper and lower limits of the DC output of the jitter ratio or queries
the current setting.
Sets the jitter ratio determination level or queries the current setting.
Queries the determination result.
Sets the DC output mode or queries the current setting.
Queries all settings related to display.
Sets the statistical value display parameters or queries the current setting.
Sets AVE display or queries the current setting.
Sets T display or queries the current setting.
Sets Dly display or queries the current setting.
Sets EQ display or queries the current setting.
Sets σ/T display or queries the current setting.
Sets the SnL display or queries the current setting.
Sets the SnU display or queries the current setting.
Sets the scale of the analog meter or queries the current setting.
Sets the time scale of the analog meter or queries the current setting.
Turns ON/OFF the numerical display or queries the current setting.
Queries all settings related to marker.
Queries all settings related to marker.
Sets the left marker or queries the current setting.
Sets the right marker or queries the current setting.
Page
10-12
10-12
10-12
10-12
10-12
10-12
10-12
10-13
10-13
10-13
10-13
10-13
10-14
10-14
10-14
10-14
10-14
10-14
10-15
10-15
10-15
10-15
10-15
10-16
10-16
10
10-18
10-18
10-18
10-18
10-18
10-18
10-18
10-18
10-18
10-18
10-18
10-19
10-19
10-19
10-19
10-19
10-19
10-9