Inhibit <<For procedures, see section 4.8>>
IM 704610-01E
You can inhibit measurements by applying an external signal to the inhibit signal input
terminal. This is possible even while the gate is open or during measurement after
arming activation. You can also select which polarity of the signal, positive or negative, is
used to inhibit measurements. The relation between the inhibit signal, gating, and
arming for pulse width jitter measurement is indicated below.
Relation between the Inhibit Signal and Gating
Inhibit
Gate open
Gate
Data signal
S1
S2
Starts measurement
Relation between the Inhibit Signal, Gating, and External Arming
Inhibit
Gate open
Gate
External arming
Data signal
S1
Starts measurement
Relation between the Inhibit Signal, Gating, External Arming, and Arming Delay
Inhibit
Gate
Arming delay
External arming
Data signal
Inhibits measurement
Not measured
S3
S4
Resumes measurement
Inhibits measurement
Not measured
S2
S3
Resumes measurement
Inhibits measurement
Gate open
Not measured
S1
S2
S3
Starts
measurement
2.4 Measurement Conditions
S5
S4
S5
S4
S5
Resumes
measurement