YOKOGAWA TA220 User Manual page 146

Digital jitter meter
Table of Contents

Advertisement

Code
Message
148
Character data not allowed
150
String data error
151
Invalid string data
158
String data not allowed
161
Invalid block data
168
Block data not allowed
171
Invalid expression
178
Expression data not allowed
181
Invalid outside macro definition
Error in communication execution
Code
Message
221
Setting conflict
222
Data out of range
223
Too much data
224
Illegal parameter value
241
Hardware missing
260
Expression error
270
Macro error
272
Macro execution error
273
Illegal macro label
275
Macro definition too long
276
Macro recursion error
277
Macro redefinition not allowed
278
Macro header not found
708
Cannot output data while measuring
IM 704610-01E
12.2 Error Code Description and Corrective Actions
Description and Corrective Action
<CHARACTER DATA> cannot be used.
Write in a data form other than {...|...|...}.
There is no delimiter to the right of <STRING DATA>.
Enclose <String data> in double quotation or single quotation
marks.
The contents of <STRING DATA> are inappropriate.
<String data> is too long or invalid character is present.
<STRING DATA> cannot be used.
Write in a data form other than <String data> form.
The data length of <BLOCK DATA> does not match.
<Block data> cannot be used.
<BLOCK DATA> cannot be used.
There is an invalid character in the <EXPRESSION DATA>.
Equation cannot be used.
<EXPRESSION DATA> cannot be used.
Equations cannot be used.
The placeholder is outside the macro.
IEEE488.2 macro function is not supported.
Description and Corrective Action
Contradictory settings are in affect.
Check the relevant communication settings.
The value of <DATA> is outside the range. Check the range.
The byte length of <DATA> is too long.
Check the length of data bytes.
The value of <DATA> is inappropriate. Check the range.
Hardware not installed.
Check for the presence or absence of options.
<EXPRESSION DATA> is not correct. Equation cannot be used. —
Macro nesting is too deep.
IEEE488.2 macro function is not supported.
Macros cannot be used.
IEEE488.2 macro function is not supported.
The macro label is inappropriate.
IEEE488.2 macro function is not supported.
Macro is too long. IEEE488.2 macro function is not supported.
Macro was recursively called.
IEEE488.2 macro function is not supported.
Macros cannot be redefined.
IEEE488.2 macro function is not supported.
The macro is not defined.
IEEE488.2 macro function is not supported.
Cannot transmit data while measurement in progress.
Stop the measurement using the STOP or SSTART command.
Ref. section
10.2
10.1
10.2
10.2
10.1, 10.2
10.1, 10.2
10.2
10.2
Ref. section
10,2
10,2
10,2
10,2
12
10.2.13,
10.2.6
12-3