Mechanical Installation
Operating Guide | VLT® AutomationDrive FC 302
Illustration 9:
Recommended Lifting Method

4.9 E1h/E2h Mechanical Installation

The E1h and E2h enclosure size is intended only for floor installation, and is shipped with a pedestal and a cable entry plate. The
pedestal and cable entry plate must be installed for proper installation.
The pedestal is 200 mm (7.9 in) and has an opening in the front to allow airflow necessary to cool the power components of the drive.
The cable entry plate is necessary to provide cooling air to the control components of the drive via the door fan, and to maintain the
IP21/Type 1 or IP54/Type 12 protection rating.

4.9.1 Securing the Pedestal to the Floor

Procedure
1. Determine proper placement of the unit, concerning operating conditions and cable access.
2. Access the mounting holes by removing the front panel of the pedestal.
3. Set the pedestal on the floor and secure using 6 bolts through the mounting holes.
Danfoss A/S © 2019.12
AQ275652476278en-000101 / 130R0709| 27