Operating Guide | VLT® AutomationDrive FC 302
4 Mechanical Installation
4.1 Items Supplied
Items supplied can vary according to product configuration.
•
Make sure that the items supplied and the information on the nameplate correspond to the order confirmation.
•
Visually check the packaging and the drive for damage caused by inappropriate handling during shipment. File any claim for
damage with the carrier. Retain damaged parts for clarification.
AutomationDrive
VLT
R
www.danfoss.com
1
T/C: FC-302N710T7E21H2XGC7XKSXXXXA0BXCXXXXD0
2
P/N: 131N2885
3
710 kW / 750 HP, High Overload
IN: 3x525-690V 50/60Hz 743/711 A (CE)
4
IN: 3x525-600V 50/60Hz 743/711 A (UL)
5
OUT: MOTOR 3x0-Vin 0-500Hz 763/730 A
800 kW / 950 HP, Normal Overload
IN: 3x525-690V 50/60Hz
IN: 3x525-690V 50/60Hz
OUT: MOTOR 3x0-Vin 0-500Hz
IP21 / TYPE 1
Tamb. 45# C/113#F at Full Output Current
Tamb. 55# C/131#F at Full Output Current Derating
SCCR 100 kA at UL Voltage range 525-600 V
ASSEMBLED IN USA
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 525-600 V
CAUTION - ATTENTION:
See manual for special condition / prefuses
Voir manuel de conditions speciales / fusibles
6
WARNING - AVERTISSEMENT:
Stored charge, wait 40 min.
Charge residuelle, attendez 40 min.
`
1 Type code
3 Power rating
5 Output voltage, frequency, and current (at low/high
voltages)
Illustration 8:
Product Nameplate for E2h Enclosure (Example)
WARRANTY
Removing the nameplate from the drive can result in the loss of warranty.
4.2 Tools Needed
•
I-beam and hooks rated to lift the weight of the drive. Refer to the Power Ratings, Weights, and Dimensions section.
•
Crane or other lifting aid to place the unit into position.
22 | Danfoss A/S © 2019.12
SN: 123456H123
866/828 A (CE)
866/828 A (UL)
889/850 A
Danfoss A/S
6430 Nordborg
Denmark
`
2 Part number and serial number
4 Input voltage, frequency, and current (at low/high voltages)
6 Discharge time
N O T I C E
Mechanical Installation
AQ275652476278en-000101 / 130R0709
Need help?
Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?