Danfoss VLT AutomationDrive FC 302 Operating Manual page 134

315-710 kw, enclosure sizes e1h-e4h
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Operating Guide | VLT® AutomationDrive FC 302
setting, the power losses can increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to http://ecos-
mart.danfoss.com/#/app/intro. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4
W.
3
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency class, see
Conditions
. For part load losses, see http://ecosmart.danfoss.com/#/app/intro.
Table 46: Electrical Data, Mains Supply 3x525–690 V AC
FC 302
High/normal overload
High overload=150% or 160% torque for a duration of 60 s.
Normal overload=110% torque for a duration of 60 s.
Typical shaft output at 525 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 525 V) [A]
Intermittent (60 s overload) (at 525 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 525 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 525 V) [A]
Continuous (at 575/690 V) [A]
Maximum number and size of cables per phase (E1h/E2h)
- Mains and motor without brake [mm
- Mains and motor with brake [mm
2
- Brake or regen [mm
(AWG)]
Maximum number and size of cables per phase (E3h/E4h)
2
- Mains and motor [mm
(AWG)]
2
- Brake [mm
(AWG)]
- Load share or regen [mm
Maximum external mains fuses [A]
Estimated power loss at 600 V [W]
Estimated power loss at 690 V [W]
134 | Danfoss A/S © 2019.12
2
(AWG)]
2
(AWG)]
2
(AWG)]
(1)
(2) (3)
(2) (3)
N560
HO
NO
HO
450
500
500
600
650
650
560
630
630
E1h/E3h
596
630
659
894
693
989
570
630
630
855
693
945
542
573
599
568
627
627
681
753
753
574
607
635
549
607
607
5x240 (5x500 mcm)
6x240 (5x500 mcm)
4x240 (4x500 mcm)
5x240 (4x500 mcm)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
4x185 (4x350 mcm)
800
7624
8676
8054
7842
8915
8357
Specifications
9.4 Ambient
N630
N710
NO
HO
560
560
750
750
710
710
E2h/E4h
E2h/E4h
763
763
839
1145
730
730
803
1095
694
694
727
727
872
872
735
735
704
704
6x240 (5x500 mcm)
5x240 (4x500 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
1200
1200
9709
9661
10059
10010
AQ275652476278en-000101 / 130R0709
NO
670
950
800
889
978
850
935
808
847
1016
857
819
11848
12253

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents