Operating Guide | VLT® AutomationDrive FC 302
FC 302
Efficiency
(3)
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Power card overtemperature trip [°C (°F)]
Fan power card overtemperature trip [°C (°F)]
Active in-rush card overtemperature trip [°C (°F)]
9.7 Fuses
1
For fuse ratings, see
.
2
Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions.) These values are based on a typical motor
efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for dimensioning of drive cooling. If the switching frequency is higher than the default
setting, the power losses can increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to http://ecos-
mart.danfoss.com/#/app/intro. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4
W.
3
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency class, see
Conditions
. For part load losses, see http://ecosmart.danfoss.com/#/app/intro.
9.2 Mains Supply
The unit is suitable for use on a circuit capable of delivering not more than 100 kA short circuit current rating (SCCR) at 480/600 V.
Supply terminals
Supply voltage
(1)
Supply frequency
Maximum imbalance temporary between mains phases
True power factor (λ)
Displacement power factor (cos Φ)
Switching on the input supply L1, L2, and L3 (power-ups)
Environment according to EN 60664-1
1
Mains voltage low/mains drop-out: During low mains voltage or a mains drop-out, the drive continues until the DC-link voltage drops below the minimum stop level, which
corresponds typically to 15% below the drive's lowest rated supply voltage. Power-up and full torque cannot be expected at mains voltage lower than 10% below the drive's lowest
rated supply voltage.
2
Calculations based on UL/IEC 61800-3.
9.3 Motor Output and Torque Characteristics
9.3.1 Motor Output (U, V, W)
Voltage output
Output frequency
Output frequency in flux mode
Switching on output
Danfoss A/S © 2019.12
N560
N630
0.98
0.98
0–590
0–590
110 (230)
110 (230)
80 (176)
80 (176)
85 (185)
85 (185)
85 (185)
85 (185)
85 (185)
85 (185)
380–480/500 V ±10%, 525–690 V ±10%
Overvoltage category III/pollution degree 2
AQ275652476278en-000101 / 130R0709| 135
Specifications
N710
0.98
0–590
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
9.4 Ambient
L1, L2, L3
50/60 Hz ±5%
3.0% of rated supply voltage
≥0.9 nominal at rated load
Near unity (>0.98)
Maximum 1 time/2 minutes
0–100% of supply voltage output
0–590 Hz
0–300 Hz
Unlimited
(2)
(1)
Need help?
Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?
Questions and answers