FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
Figure 8-31 M.2 FRU indicators
Table 8-2 Indicator status
Indicator
M.2 FRU fault
indicator
M.2 FRU activity
indicator
----End
8.4.11 Removing a Processor
● Only Huawei technical support or personnel authorized by Huawei can remove
● Do not wear ESD gloves during processor replacement. The gloves may catch
Procedure
Step 1 Power off the server node.
For details, see
Step 2 Remove the server node.
For details, see
Step 3 Place the server node on the ESD workstation.
Step 4 Remove the air duct.
For details, see
Step 5 Determine the position of the processor.
Issue 07 (2019-12-20)
NO TICE
the processors from Huawei servers.
on pins on the processor socket and damage it.
8.3.2 Power-Off
8.3.3 Removing an XH321
8.4.23 Removing the Air
Copyright © Huawei Technologies Co., Ltd.
Description
● Off: The M.2 FRU is running properly.
● Blinking yellow: The M.2 FRU is being located, or
RAID is being rebuilt.
● Steady yellow: The M.2 FRU is faulty or not
detected.
● Off: The M.2 FRU is not in position or is faulty.
● Blinking green: Data is being read, written, or
synchronized.
● Steady green: The M.2 FRU is inactive.
Procedure.
V5.
Duct.
8 Parts Replacement
67