Huawei FusionServer Pro XH321 V5 V100R005 Maintenance And Service Manual page 84

Server node
Hide thumbs Also See for FusionServer Pro XH321 V5 V100R005:
Table of Contents

Advertisement

FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
3.
4.
5.
Figure 8-43 Installing the heat sink
Step 11 Install the air duct.
For details, see
Step 12 Install the server node.
For details, see
Step 13 Power on the server node.
For details, see
----End
Issue 07 (2019-12-20)
Horizontally holding the processor and heat sink, align the notched corner on
the heat sink with the notched corner on the processor socket, and place the
processor and heat sink downwards on the socket along the guide sleeves.
NO TICE
Keep the processor and heat sink parallel with the mainboard to prevent
damage to processor socket pins.
Use a Phillips screwdriver to tighten the two diagonal screws (marked 1 on
the label) on the heat sink. See (1) in
Use a Phillips screwdriver to tighten the four screws (marked 2 in the label) in
the middle of the heat sink in a diagonal sequence. See (2) in
8.4.24 Installing the Air
8.3.4 Installing an XH321
8.3.1 Power-On
Copyright © Huawei Technologies Co., Ltd.
Figure
8-43.
Duct.
V5.
Procedure.
8 Parts Replacement
Figure
8-43.
76