FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
Step 2 Remove the server node.
For details, see
Step 3 Place the server node on the ESD workstation.
Step 4 Remove the air duct.
For details, see
Step 5 Take a spare memory module.
Step 6 Check the positions and installation guidelines of the memory modules.
For details, see
Figure 8-46 Memory slots
Step 7 Install the memory module.
1.
2.
Issue 07 (2019-12-20)
8.3.3 Removing an XH321
8.4.23 Removing the Air
2.3.5 Memory Installation
Open the two memory module ejectors on the memory slot.
Figure 8-47 Opening the memory module ejectors
Align the edge connector of the memory module with the alignment key of
the memory slot, and insert the memory module in the slot.
The two memory ejectors are closed automatically after the memory module
is firmly seated.
Do not touch the edge connector on a memory module with bare hands. Before
installing a memory module, ensure that the edge connector is not contaminated.
Copyright © Huawei Technologies Co., Ltd.
V5.
Duct.
Positions.
8 Parts Replacement
79