Table A-6 RAS features
Module
CPU
DIMM
PCIe
UPI
System
Issue 07 (2019-12-20)
Feature
Corrected Machine Check
Interrupt
Failed DIMM Isolation
Memory Thermal
Throttling
Rank Sparing
Memory Address Parity
Protection
Memory Demand and
Patrol Scrubbing
Memory Mirroring
Single Device Data
Correction
Device Tagging
Data Scrambling
PCIe Advanced Error
Reporting
Intel UPI Link Level Retry
Intel UPI Protocol
Protection via CRC
Core Disable for Fault
Resilient Boot (FRB)
Copyright © Huawei Technologies Co., Ltd.
Description
Corrects error-triggered interruption.
Identifies a faulty DIMM and isolates it
from others before it is replaced.
Automatically adjusts DIMM
temperatures to avoid damage due to
overheating.
Allocates some memory ranks as
backup ranks to prevent the system
from crashing due to uncorrectable
errors.
Detects memory command and
address errors.
Corrects errors upon detection. If these
errors are not corrected promptly,
uncorrectable errors may occur.
Improves system reliability.
Provides a single-device multi-bit error
correction capability to improve
memory reliability.
Degrades and rectifies DIMM device
faults to improve DIMM availability.
Optimizes data stream distribution
and reduces the error possibility to
improve the reliability of data streams
in the memory and the capability to
detect address errors.
Improves server serviceability.
Provides a retry mechanism upon
errors to improve UPI reliability.
Provides cyclic redundancy check
(CRC) protection for UPI packets to
improve system reliability.
Isolates a faulty CPU core during
startup to improve system reliability
and availability.
A Appendix