Step 14 Check the indicator status. If the health status indicator is steady green, the server
node is running properly.
For details, see
Step 15 To burn the original ESN into the new mainboard after replacement, contact the
technical support.
If the original device SN is not burnt in the new mainboard, the iBMC and OS
cannot obtain the device SN. This may affect the running of some services or the
monitoring and management on the device.
Step 16 After the mainboard is replaced, the LOM is replaced and the MAC address of the
LOM is changed. If the LOM is used for transferring data, you need to configure
the LOM data.
Step 17 After the mainboard is replaced, the iBMC and BIOS settings are restored to the
default settings of the new mainboard. Configure the iBMC and BIOS based on
service requirements.
Step 18 Upgrade the iBMC, BIOS, and CPLD to the versions used before the replacement
(recommended) or to the latest versions.
For details, see
----End
Issue 07 (2019-12-20)
2.1.2 Indicators and
NO TICE
● If you have iBMC and BIOS configuration files imported before the replacement of the
mainboard, you can import the configuration files after the replacement. However, the
exported configuration files do not contain password information. You need to manually
configure the password for the iBMC user. For details, see iBMC WebUI > Configuration
> Import/Export in
● The iBMC and BIOS configuration files exported from the iBMC contain the
configuration list. For details, see "Configuration File Description" in
X6000 Server iBMC User
● The iBMC supports import and export of configuration files from version 2.32.
● If the iBMC/BIOS configuration files are not imported before you replace the mainboard,
manually configure the iBMC and BIOS data after the replacement.
FusionServer Pro High-Density Server Upgrade
Copyright © Huawei Technologies Co., Ltd.
Buttons.
FusionServer Pro X6000 Server iBMC User
Guide.
8 Parts Replacement
Guide.
FusionServer Pro
Guide.
102

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fusionserver pro xh321 v5V100r005

Table of Contents