2.
Step 10 Install the processor and conjoined heat sink.
1.
2.
Issue 07 (2019-12-20)
Figure 8-42 Installing the processor carrier
Place the assembled processor and heat sink upside down on the desk, and
check that the processor carrier and the heat sink are firmly secured. If the
processor carrier is not firmly buckled with the heat sink, press the processor
carrier to secure it.
Remove the processor socket cover.
NO TICE
When removing the socket cover, keep it parallel with the board to prevent
damage to pins.
Shine a light at various angles onto the processor socket to check for twisted
pins, foreign matter, and pad damage.
NO TICE
If bent pins or foreign matters are found or the bonding pad is damaged, stop
the operation and contact Huawei technical support.