Step 6 Align the positioning pins on the air duct with the fixing holes on the chassis
according to the instructions on the air duct. Vertically place the air duct
downwards.
Figure 8-66 Installing the air duct
Step 7 Install the server node.
For details, see
Step 8 Power on the server node.
For details, see
----End

8.4.25 Removing the Mainboard and Server Node Case

Procedure
Step 1 Record the firmware (iBMC, BIOS, and CPLD) versions of the mainboard to be
replaced.
Step 2 Check the iBMC and BIOS configurations.
Step 3 Export the iBMC or BIOS configuration files.
For details, see iBMC WebUI > Configuration > Import/Export in
Pro X6000 Server iBMC User
Issue 07 (2019-12-20)
8.3.4 Installing an XH321
8.3.1 Power-On
On the iBMC WebUI, choose Information > System Info > Mainboard Info to
obtain the information.
On the iBMC CLI, run the ipmcget -d version command to obtain the
information.
Copyright © Huawei Technologies Co., Ltd.
V5.
Procedure.