Festo CMSX-C-U-F1 Series Manual page 46

Hide thumbs Also See for CMSX-C-U-F1 Series:
Table of Contents

Advertisement

CMSX-...-C-U-F1-...
Note
During initialization the process valve is moved to the end positions. As a rule, there­
fore, initialization may only be performed during the commissioning phase – dependent
on the system.
Display
Description
MENU 6 INIT
Starts automatic initialization
Autoinit
Here, the drive is moved into the end positions. Automatic initialization takes a
certain amount of time.
Starts user-guided initialization
Userinit
With user-guided initialization, each individual step of initialization is started by
pressing the Add button by hand.
Resets all current settings to the presettings valid from the plant (delivery
Fcty Rst
status è Tab. 5).
Resets all current settings to the individual presettings previously saved with
Sytm Rst
SET AS DEF.
Saves all current settings as individual presettings.
SET AS DEF
1) In initialization, the positioner determines the swivel angle and a maximum positioning time. In doing so, it coordinates control of
the fast-switching valves with the direction of rotation of the potentiometer. VP and SP then behave synchronously.
Tab. 24
Initialization menu (6)
MENU
6 INIT
1
Caution: Function is activated. The drive is
moved in initialization!
Fig. 34
Movement in the Initialization menu (6) – example AutoInit
Operation
Briefly press Add
Briefly press Sub
46
3
*INITIA*
6
Autoinit
Userinit
Fcty Rst
...
Selection in the menu
1
Continue to the next selection
2
Back to the previous selection
1)
(è Section 7.7.3)
1)
. Here, the drive is moved into the end positions.
7
AutoInit
24--
2
1
AutoInit
24--
AutoInit
2
Automatic sequence of initialization
Festo – CMSX-...-C-U-F1-... – 1506a English
1
...
OK
1
2