PCX 256 PROGRAMMING MANUAL
5 . 1 8 E n g i n e e r R e s e t O p t i o n s
The Engineer Reset Options are used so that once an alarm has occurred; the PCX system can
only be reset by an engineer code, anti code or red care reset from the alarm receiving centre.
Option
Engineer Restore
of Intruder
Engineer Restore
of HU
Engineer Restore
of Tamper
Engineer Restore
of Soak
Engineer Restore
of Confirmed
Engineer Restore
of Faults
Anti Code
Restore
Engineer Restore Options
Using the
and
'ENGINEER RESTORE OPTIONS?' Press the
key
Eng Restore Int
Enter
: for No (Default)
Enter
: for UK Intruder
Press the
key.
Repeat the above options for the restores:
Tamper, Soak, Confirmed, Faults and Anti Code
Restore. (Enter
You will be returned to the Engineer Menu.
Page: 48
Function
Following an intruder alarm, an engineer must reset the system before it can
be used again. Please select 'UK Intruder' to enable this, 'Secure Intruder'
should not be used. This will not interfere with the generation of an
emergency alarm. The default is NO
Following a Hold Up, Input HU or Duress alarm, an engineer must reset the
system before it can be used again. This will not interfere with the generation
of a Fire or Gas (emergency) alarm. The default is NO
Following a Tamper alarm, an engineer must reset the system before it can
be used again. This will not interfere with the generation of an emergency
alarm. The default is YES
In the event of an input with the 'soak' attribute triggering whilst the system is
armed, the system must be reset by an engineer before it can be used
again. This will not interfere with the generation of an emergency alarm.
The default is NO
Following a confirmed alarm, an engineer must reset the system before it
can be used again. The default is NO
If selected, an engineers code will only be able to reset the following faults:
STU/ATE telecom fail, Modem fail, STU/ATE single path fail, Telecom line
fail, Battery disconnect, Batt charge, Batt load, Excessive charge, Battery
critical, Device fail. The default is NO.
Enables the system to display an anti-code whilst awaiting an Engineer
reset, which can be used to generate a special reset code. The default is
NO.
V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
E N G I N E E R R E S T O R E O P T I O N S
keys, scroll to
: for No,
: for Yes)