Engineer Reset Options; Review Logs - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

Site Options Programming
1. Press or to scroll to 'SITE OPTIONS'. Press .
2. 'Set With Fault' will be displayed. Use [ or ] to enable/disable
each option and press . Repeat for all functions. The engineer
menu will be displayed once all functions have finished.

4.17 Engineer Reset Options

The Engineer Reset Options are used so that once an alarm has occurred; the Enforcer 32-WE system
can only be reset by an engineer code, anti-code or red care reset from an Alarm Receiving Center
(ARC).
4.17.1 Engineer Restore of Intruder
If 'UK Intruder', an Engineer code must be used to reset the Enforcer 32-WE after an alarm.
'Secure Intruder' should not be used.
4.17.2 Engineer Restore of Hold Up
If 'YES', an Engineer code must be used to reset the Enforcer 32-WE after an Hold Up, Input Hold
Up, or Duress activation.
4.17.3 Engineer Restore of Tamper
If 'YES', an Engineer code must be used to reset the Enforcer 32-WE after a tamper activation.
4.17.4 Engineer Restore of Soak
If 'YES', an Engineer code must be used to reset the Enforcer 32-WE after an input that is on
'soak' has triggered when the Enforcer 32-WE is set.
4.17.5 Engineer Restore of Confirmed
If 'YES', an Engineer code must be used to reset the Enforcer 32-WE after a confirmed alarm has
occurred.
4.17.6 Engineer Restore of Faults
If 'YES', an Engineer code must be used to reset the Enforcer 32-WE after the following faults:
ATE telecom fail, Modem fail, ATE single path fail, Telecom line fail, Battery disconnect, Batt
charge, Battery load, Excessive charge, Battery critical and Device fail.
4.17.7 Anti-Code Restore
If 'YES', the Enforcer 32-WE will display an Anti-Code, to which can be used to generate a special
reset code (usually from the ARC) to reset the Enforcer 32-WE.
NOTE: that if Anti-Code is selected, this will coincide with the options that have been selected
previously. For example, if 'Engineer Restore Intruder' is selected, and Anti-Code is selected,
then an anti-code will be produced on intruder activation.
Engineer Reset Options Programming
1. Press or to scroll to 'SITE OPTIONS'. Press .
2. 'Engineer Restore Intruder' will be displayed. Use [ or ] to
enable/disable each option and press . Repeat for all functions.
The engineer menu will be displayed once all functions have
finished.

4.18 Review Logs

The control panel has two Event Logs, which are time and date stamped. The first log which is a
panel log, records all events that occur on the Enforcer 32-WE, i.e. Users entering their codes to arm
or disarm areas, alarm events, failures to arm etc.
The second log which is an access log, only records access control events.
4.18.1 Panel Log
The Panel log records all events that occur on the Enforcer 32-WE, i.e. Users entering their codes
to set or unset areas, alarm events, failures to set etc. Pressing will give more information of
the display (for example, shows which user unset the Enforcer 32-WE).
Page: 23
SITE OPTIONS?
Set With Fault
Yes
ENGINEER RESTORE
OPTIONS?
Eng Restore Int
No
[1]
[0]