CHANGE INPUTS

CHANGE INPUTS?
A total of 66 zones can be programmed on the system. All zones are unused by default. To save any programming
the Engineer menu must be exited.

INPUT TYPES

For all input type options, please see
Most commonly used input types:
[06] Intruder
[07] Final Exit
[08] Entry Route
[13] Day Alarm.
Please note:
1. If an alarm is triggered from an Entry Route zone, it will be stored for 2 seconds before an alarm is
activated. If a Final Exit zone is triggered within this time, the system will start the entry time, rather than
an intruder alarm.
2. Zones may be automatically omitted at the time of reinstatement, which is at the end of confirmation
time. This is irrelevant of whether the zone has the attribute 'Omittable' set to 'Yes' or 'No'

INPUT AREAS

The system supports up to four areas and could be used as follows:
Area A:
Area B:
Area C:
Area D:
Input Area (Any/All)
In some installations a 'common' area may be required. A common area is an area that only arms when other
specific areas become armed. Example: An entry and exit reception area in a building may only need to be armed
if both the offices and warehouse are armed. If the office in Area A is armed, but the warehouse in Area B is still
occupied, then the reception would still need to be inactive so people would be able to leave the premises
via the entry / exit reception route. One zone can be allocated to one or more areas. In this example the zones
located in the reception area will be programmed so that the reception zones will be in Area A and Area B, so
these zones must have the Input Areas attribute set as 'ALL' programmed.
Area A: Office - Zones = 3, 4, 5
Reception zones – 1 and 2 are programmed into both Areas A and B, with both zones' Input Areas attribute
configured as 'ALL' . The Reception area zones will now only become active if both Area A and Area B are both
armed.
Please note: All zones in a common area must be programmed as 'Entry Route' or 'Final Exit' and the
'Common Lobby' option in Site Options needs to be enabled.
16
Input [--]
"Appendix B - Input Types" on page
All Factory
Reception Only
Offices Only
Factory Floor Only
Area B: Warehouse - Zones = 6, 7, 8
ENFORCER V11 PROGRAMMING GUIDE
51.