2. Fitting and pneumatic installation

2.3.3 Position measuring system

Drive
Position measuring system
DGCI
Permanently integrated position
measuring system.
DGP(L)
External position measuring
system of type MLO−POT−...−TLF.
DNCI
Integrated position measuring
system.
DNC
External position measuring
system of type MLO−POT−...−LWG.
DNCM
External position measuring
system already mounted on
delivery
DSMI
Integrated position measuring
system.
Tab. 2/3: Instructions for mounting the position measuring systems
2−10
Tab. 2/3 provides instructions on mounting the displacement
encoder.
Mounting instructions
·
·
·
When used under difficult environmental condi
tions (dusty environment):
·
·
·
·
·
Only use a displacement encoder and drive
with the same stroke length. The displacement
encoder must be longer than the drive stroke
used. An electric reserve 0.3% of the nominal
length must be available.
For safe and quick mounting of the displace
ment encoder: Use the BB−TLF−DGPL−...
mounting kit.
Mount the displacement encoder electrically
isolated on the mounting surface using the
clamps provided.
Mount the displacement encoder with the
actuator slide facing downwards. The draining
edge on both sides prevents excessive dirt
from accumulating on the bearing surface.
Use only a displacement encoder and standard
cylinder with the same stroke length.
Mount the displacement encoder and standard
cylinder symmetrically (middle of the displace
ment encoder stroke must be aligned with the
middle of the entire cylinder stroke).
Always leave the displacement encoder
mounted on the standard cylinder.
Observe the instructions in the operating
instructions.
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH