Determining The Current Consumption - Festo CPX-CMAX-C1-1 Mounting, Installation And Diagnostics

Cmax axis controller
Hide thumbs Also See for CPX-CMAX-C1-1:
Table of Contents

Advertisement

3. Electrical installation

3.4.1 Determining the current consumption

Calculations
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
The current consumption of a CMAX system depends on the
number and type of the modules connected to the axis inter
face.
Recommendation:
Use a closed−loop regulated power supply.
·
When selecting the power supply unit, check that it pro
·
vides a sufficient output. Calculate the total current con
sumption, if necessary.
Tab. 3/10 and Tab. 3/11 show the current consumption for a
positioning system.
Observe the instructions on selecting the power supply unit
in the CPX system description.
CMAX current consumption from U
CPX terminal
Typical current consumption
Maximum current consumption
Tab. 3/10: Current consumption via U
CPX terminal
Current consumption from U
Typical current consumption for the VPWP valve
Maximum current consumption for the VPWP voltage
output
Max. current consumption for the digital VPWP output
(clamping unit/brake)
Maximum total current consumption
Tab. 3/11: Current consumption from U
CPX terminal
of the
EL/SEN
of the
EL/SEN
of the CPX terminal
VAL
of the
VAL
200 mA
300 mA
1 A
0.5 A
0.5 A
2.5 A
3−13